Photo: Jonathan Castañeda / UnsplashA pressure class sets the flange’s pressure–temperature rating and its dimensions. Higher classes have thicker flanges, larger bolt circles and more or bigger bolts, so a Class 150 valve will not bolt to a Class 300 flange of the same size.
Ratings fall as temperature rises and depend on material, so always check the real service condition rather than the class number alone.
Our test pressures
Every valve is tested to API 598 before despatch. Shell and seat test pressures by class, in kg/cm² (psig):
| Class | Shell | Seat |
|---|---|---|
| 150 | 32 (450) | 22 (315) |
| 300 | 79 (1125) | 57 (815) |
| 600 | 156 (2225) | 115 (1630) |
| 900 | 236 (3350) | 172 (2445) |
| 1500 | 392 (5575) | 287 (4080) |